Publications


2001

A., MRMUNGAGILBERT.  2001.  (2001). Concrete Practices in Kenya (2001). Jomo Kenyatta University of Agriculture and Technology Symposium.. Presented at the Commonwealth Association of Surveying and Land Economy (CASLE) and the International Federation of Surveyors (FIG) Seminar, Harare,. : Survey Review Abstract
Towers are typical structures that can be found in many urban and rural landscapes the world over. From their basic design, they are usually exposed to severe environmental loads. It is therefore prudent to carry out periodic maintenance that includes checking that they are correctly aligned. This paper describes a method that was used for the re-alignment of a guyed tower in Limuru, Kenya. Angular and distance observations, made from two observation points detected a vertical misalignment that was larger than the acceptable tolerance of l/400. An iterative re-alignment procedure was then applied, resulting in an acceptable final misalignment of 1 / 520.

1995

A., MRMUNGAGILBERT.  1995.  (1995). Construction practices on expansive soils in Kenya. Proceedings of Symposium on Unsaturated Soil Behaviour and Applications. 22-23 August 1995, University of Nairobi, Kenya. Pp 146-151.. Presented at the Commonwealth Association of Surveying and Land Economy (CASLE) and the International Federation of Surveyors (FIG) Seminar, Harare,. : Survey Review Abstract
Towers are typical structures that can be found in many urban and rural landscapes the world over. From their basic design, they are usually exposed to severe environmental loads. It is therefore prudent to carry out periodic maintenance that includes checking that they are correctly aligned. This paper describes a method that was used for the re-alignment of a guyed tower in Limuru, Kenya. Angular and distance observations, made from two observation points detected a vertical misalignment that was larger than the acceptable tolerance of l/400. An iterative re-alignment procedure was then applied, resulting in an acceptable final misalignment of 1 / 520.

1982

A., MRMUNGAGILBERT.  1982.  (1982).Rational Design of Internally Sealed Concrete. MSc. Thesis , University of Strathclyde (UK).. Presented at the Commonwealth Association of Surveying and Land Economy (CASLE) and the International Federation of Surveyors (FIG) Seminar, Harare,. : Survey Review Abstract
Towers are typical structures that can be found in many urban and rural landscapes the world over. From their basic design, they are usually exposed to severe environmental loads. It is therefore prudent to carry out periodic maintenance that includes checking that they are correctly aligned. This paper describes a method that was used for the re-alignment of a guyed tower in Limuru, Kenya. Angular and distance observations, made from two observation points detected a vertical misalignment that was larger than the acceptable tolerance of l/400. An iterative re-alignment procedure was then applied, resulting in an acceptable final misalignment of 1 / 520.